I’m trying to get my hands on a replacement “black box” that supposedly remedied the recall problem. Owners were instructed to contact their RV dealer or a Norcold Authorized Service Center to arrange a service date. Copyright 2020 PC Media, Inc. All Rights Reserved. This is just one of those things to look for periodically and be aware of. Norcold 1200 Series Recall We would like to begin by discussing some facts about the Norcold 1200 Series recall … As mentioned before, having the recall done on your fridge is priority #1. The little red light on it is not on. This recall is the NHTSA 10E-049 campaign or Norcold fix - Norcold control. I bought my current RV (2002 Holiday Rambler Vacationer) in January from LazyDays, so we checked everything before I drove away. 1210 Ultraline operates on AC, DC, or LP gas and, thanks to the smart side-by-side, four-door layout, keeps cold air loss at a minimum, saving you energy. All labor to inspect and tighten the unused connection on the propane gas valve is at no charge to the consumer. We appreciate any assistance you could provide to help us notify the owners of vehicles built during this time frame. Continued propane gas mode operation of a refrigerator under this recall could result in a fire causing injury or death. The proposed fix was to install a high temperature sensor. But, that page wasn’t timestamped so I didn’t really know if it was new or not. The issue is with the cooling unit. Yay. It seems to be the larger fridges with 4 doors that are most problematic. Helpful. Just the part has now failed after 10 Years. Owners who have had the heater element replaced in one of these cooling units should call: 1-800-767-9101 to get their refrigerator upgraded to current product configuration. Norcold determined that certain gas valves were exhibiting low flow and adjustments were being made to an unused connection on the propane gas valve of these refrigerators. It is also a one-way shutdown, meaning that you can’t turn it back on. These refrigerators electronic controls operate on 12 volt DC. Now, to be clear… that sensor isn’t really a fix. Norcold 1200, 1201, 1210, and 1211 Parts and Products for Sale! In a Facebook group I belong to, somebody dropped a link to the Thetford / Norcold cooling unit recall page. Norcold: Model: 637360: Fits: Norcold Refrigerators Series: 2118/ 1210 : Color: Black: Features: To Detect Improper Operation Of The Cooling Unit. Both of them are highly flammable. The refrigerator’s model and serial number are located inside the fresh food compartment. Total time allowance for the required recall service is 0.5 hours. These refrigerators may have cooling units with a cooling unit serial number between 700000 to 13085759. Lastly, some people believe that switching out the cooling unit for an Amish-built unit is better and safer. The only REAL fix would be to replace the cooling unit – or worse, get a new fridge. Some potential customers and a few RV repair technicians have stated that there is not a difference between the Fridge Defend and the Norcold Recall, even worse, it is the party line to state that boiler protection such as the Fridge Defend is not necessary! Click here for the Service Bulletin with detailed instructions how to access and tighten the unused connection on the propane gas valve on these refrigerators. It is important to implement this safety enhancement to prevent an unsafe elevation in the temperature of the cooling unit should the unit fail in operation. Followers 2. Norcold high temperature sensor kit. Here’s a video which shows it: I'm not a full-timer. These are hard to get! Even if your refrigerator was retrofitted as part of a previous recall, it is necessary to have it retrofitted with the new HTS safety device to minimize the risk of injury or death due to fire. As a result of false triggers for the Norcold recall, operators get into the habit of resetting or bypassing the Norcold recall. Campaign Number: 10E049000 Date Manufactured: Oct 15, 2010 Vehicles Affected: 151795 This notice is in accordance with requirements of the National Traffic and Motor Vehicle Safety Act and the Canada Motor Vehicle Safety Act. Monitors The Surface Temperature Of The Boiler. The very late models of the Norcold 1210 cooling unit are the same as all 1200 series except 1210's have a smaller diameter AC elements. They called Norcold directly and got the info direct from them. No LP gas power operation should occur because it could create an unsafe condition. {"email":"Email address invalid","url":"Website address invalid","required":"Required field missing"}, Norcold Refrigerator Recall: What You Need To Know, I'm not a full-timer. The Fridge Defend temperature sensor wiring exits the insulation at the top, away from the electrical heating wires. Other recalled refrigerators may have been purchased as a replacement during the same period. Use HVAC aluminum tape to re-attach the insulation on the older foil type boiler housing. I don’t know how much of it is true and how much isn’t, but even the lack of dates on the recall information page makes it confusing. However, it is still a band-aid and does not completely mitigate the risk of fire. 1210 refrigerator pdf manual download. Interesting that our insurance company has a lawsuit against the company as we are the second fire claim they have. Please contact Norcold’s Recall Center at 1-800-444-7210 (Option 1) with any questions. Elegant, durable, and convenient. Click here to check it out. Nothing really new. Norcold, Inc. cannot accept responsibility if you do not immediately arrange to take your refrigerator into a Dealer/Service Center for repair. IMPORTANT: Some of the involved refrigerators may be in your vehicle inventory. Here we go again.”. Cooling unit serial number range is from 700000 to 13085759. Perhaps help out a few other people. A defect inside the unit (the boiler tubes). Unknown Norcold 1210 Equipment Recall 10E049000. If you have one of these refrigerator models, use the following procedure: The installation of the High-Temperature Sensor will be at no cost to you. Polar Compressor Refrigerators; Polar Series RV Refrigerator; Large 2-door RV Refrigerators; Large 4-door RV Refrigerators It is a very dangerous situation. Norcold Inc. has decided to recall certain 1200, 1201, 1210 and 1211 model gas/electric refrigerators with serial numbers from 315525 to 13088811, non-consecutively. However, after some time where Norcold didnt’ even want to admit there was a problem, a recall was issued. This sensor would detect a buildup of heat, indicating a breach. Your family will love the user-friendly features, the exterior beauty, and the organized and spacious interior. They also have it labeled to make it very clear. Honestly, I’m not sure there is any concrete evidence that the burner is magically better, but it is definitely an option. With some of the late Norcold 1210 refrrigerators, the refrigerator case foam cavity is a little different to the cooling unit foam block and a small amount of foam will need to be trimed for correct fit. We can do that due to my work at, a really thoroughly researched post about the Norcold issue. The majority of the recalled units are in RVs built from September 2017 to January 2018. I wonder if my problem could be the Norcold Recall box on the unit. The most disappointing fact about this Norcold recall is that they can't seem to find the end of it. I took a peek online to see if any of the Norcold 1210 door gaskets - iRV2 Forums The runaround. 1200, 1201, 1210 and 1211, 4 door refrigerators with cooling unit serial numbers ranging from 700000 to 13085759. I contacted my local RV maintenance people. This sensor would detect a buildup of heat, indicating a breach. It is a band-aid. Purpose: This service bulletin is intended to provide safe procedures and troubleshooting steps that provide diagnostic procedures to aide (3) 3 product ratings - NORCOLD 633299 2-Way Optical Control Board Kit, For 1200 Series Refrigerator Buy for a replacement or a spare. Norcold Inc. has decided to recall certain 1200, 1201, 1210 and 1211 model gas/electric refrigerators with serial numbers from 315525 to 13088811, non-consecutively. If you have any questions, please contact us at 1-800-767-9101. Here is the Claim Form. Yeah… me, too. I SEE THIS GOING TO COURT if something isn’t done by Norcold soon. I am not sure about other models, you should contact Norcold about your model. If detected, it would cut off power to the refrigerator control board and shut down the fridge automatically. If you ever smell any ammonia, shut down the refrigerator and seek immediate service. Apparently, I’m fine. We can do that due to my work at Blog Marketing Academy. These tubes can corrode prematurely and this results in propane gas escaping. N841, N821, N641, N621 and 1082 gas/electric 2 door refrigerators, having cooling units with serial numbers from 1038000 to 1099000. Contact your dealer, a Norcold authorized service center or Norcold’s Recall Center at. Any suggestions welcome …. The Norcold, Inc. refrigerators listed below have been recalled. The recall had already been done, however there was some kind of control board thing they did on it for me. If the serial number falls in the range of. If you have one of the recalled refrigerators you should: Click here to see if a N305 or N306 serial number falls under this recall or check the status of a recalled unit. Norcold refrigerator Recall. Even if your refrigerator was repaired as part of a previous recall, it is necessary to have it repaired again to minimize the risk of injury or death due to fire. Propane gas escaping next to a heat source means high risk of fire. These are just a few of the features that make Norcold 1210 Ultraline one of the best RV refrigerators out there. A safety recall exists in certain Norcold gas/electric refrigerators. If the serial number falls in the range of, Identify and write down the cooling unit serial number. norcold 4/11/2016 parts list 1210 series gas electric models panel type doors 1210 1210c 1210im1210acimd 1210imc 1210imd 1210impfs 1211im 1211imc 1210acss wrap type doors 1210bk 1210imbk 1210imbkd 1210imss 1210imcss 1210imssd 1210imcssd 1210ss 1211imss 1211imwpm 1211wpm model identificaton codes Aside from that, continue camping and having fun. JerArdra, from the RVForum, also posted a rather ingenious hack where he installed a smoke alarm and fire extinguisher specific to his refrigerator. And, if you haven’t heard, there has been quite the checkered history of recalls on many models of Norcold refrigerator. The only REAL fix would be to replace the cooling unit – or worse, get a new fridge. . 23 people found this helpful. Norcold Norcold 1210 Refrigerator (4-door unit without ice maker) 12 cubic ft. $4,761.51 $3,704.81 (You save $1,056.70) SKU: 1210 Condition: New Availability: This is a special order part with a lead time of approximately 4-6 weeks. Got a Norcold refrigerator inside your RV? This is a bad habit, if there is a failure of the fridge and one bypasses the recall, or turns off the ARP Control, a dangerous situation may occur. This unused connection may have been loosened during the manufacturing testing process. The 1210 AC series cools only on AC power. (No gas leak can occur during AC or DC operation.). 3) Norcold Refrigerator Cooling Unit Temperature Monitor Control 637360 kit started its life as an NHTSA recall for the Norcold 1200, 1201, 1210 & 1211 refrigerators as a result of fire issues. We appreciate your cooperation and assistance in conducting this safety recall. The login page will open in a new tab. If you want a more thorough history of the Norcold issue, Malia’s Miles has a really thoroughly researched post about the Norcold issue. A remedy kit, and the labor to install it, is free to the consumer. I had to wait 3 weeks for the parts to arrive. Moreover, you could be personally liable to third parties for property damage or bodily injuries resulting from your failure to have your refrigerator immediately repaired. After logging in you can close it and return to this page. Fridge works great! Norcold, Inc. 5.0 out of 5 stars Right part. NORCOLD 1200 1210 RECALL HTS KIT. She also links out to a bunch of forum discussions on the issue. Turn the manual shut-off valve to OFF and operate it only on AC or DC power until the defect is repaired. If the serial number for your refrigerator model is within the specified range as listed below, the refrigerator’s gas valve needs to be remedied immediately. This enhancement seeks to minimize the risk of injury or death due to fire. Immediately switch your refrigerator’s controls to AC power (or DC power, if available, while in transit). Please log in again. This is a very minor trim, about 1/2 inch of foam trimed off.. If you do much research into the history of the Norcold recalls, you get a lot of stories about the company being… less than upfront. Subject: Norcold recall, NHTSA assigned number 18E013, for models N305 and N306 refrigerators with serial numbers ranging from 27378283 to 28230836, non-consecutively. You are prohibited from selling a product which has been identified by this corrective action campaign unless the product has first received the specified corrective action. Norcold 1210 Reading No AC On Panel. Comment Report abuse. When the boiler tubes develop a crack, the unit will leak ammonia and hydrogen. I purchased a brand new model 1210IM in July, 2010 and it was included in the recall in September. Only operate the refrigerator on electric until recall service has been performed. Norcold 1210 Reading No AC On Panel Sign in to follow this . Call me... a half-timer. And that’s no fun. Affected Models: 1200,1201,1210 and 1211 four door models, 1996-2010. Having the Norcold high temperature safety switch (recall HTS) installed and functioning properly is something that is federally mandated and you run the risk of a fire if ignored or bypassed. I'm wiring in my new ARP 2.1 with fan control into a new Norcold 1210 that has the recall high temperature box pre-installed by Norcold next to the control box. Find a Dealer; Home; Products. Recalls 08E-030, 09E-026 and 09E-027 involved the installation of a thermal switch on the cooling units manufactured from December 1996 through December 2002. Just had a new Norcold refrigerator insatalled 8- 22- 18 After hour of installation time, our repaireman turns it on and it doesn’t work, And Norcold is giving my RV repair cost. I'm an avid lover of going camping and traveling in our Holiday Rambler Vacationer motorhome. So, you should inspect the inside of your RV refrigerator periodically. So, I thought I’d look into it myself. Thetford 1210: Supplementary Guide. You will be reimbursed for the appropriate time at your standard labor rate. Click or tap the image to enlarge. Comes with new module and sensor only. Federal law requires the corrective action to be completed on these refrigerators before retail delivery. This image is of a letter from Norcold which describes the Norcold 1200 series recall kit function. I'm told by norcold that I need the shim/seal replaced. For example, a 121XIMSS has a factory installed These refrigerators were installed as original equipment in vehicle model years 1997 to 2010. See what I could find. Just recently, the matter came to my attention once again. This is a new recall campaign to include all 1200, 1201, 1210 and 1211 models. Contact a servicing Dealer/Service Center to arrange a service date soon. Refrigerator model and serial numbers can be viewed by looking on the inside right of your refrigerator cabinet. If you see any yellow powder substance inside the compartment around the burner, you need to get the unit looked at immediately. Contact your dealer, a Norcold Authorized Service Center or Norcold’s Recall Center at. My first reaction: “Ah crap. The people on Facebook seemed to think it was new. The refrigerator’s model and serial number are located inside the fresh food compartment. I don’t remember if it was part of a recall. I … With the action taken with this letter Norcold is voluntarily extending a recall of all 1200, 1201, 1210 and 1211 models to include units produced from January 1, 2003 to October 7, 2010. On March 7, 2018, Norcold announced and undertook a motor vehicle equipment safety recall (18E013) to address a potential safety defect at the propane gas valve on Norcold refrigerator model numbers N305 and N306 with serial numbers ranging from 27378283 to 28230836, non-consecutively, built from Sept. 15, 2017 to Feb. 15, 2018. However, this matter can be confusing. Read more. Our first priority is the safety of our products and the satisfaction of our customers. It came as standard equipment on fridges such as the 1210 & 2118 after the year 2010. The gas valve in your refrigerator will be replaced at no charge. I'm an avid lover of going camping and traveling in our Holiday Rambler Vacationer motorhome. The only solution, if it trips, is a cooling unit replacement or a new fridge. recall notice to all owners of a number of the company’s refrigerator models in regard to an issue with the cooling unit that could lead to hazardous fire norcold 11/07/2017 parts list 1210 series gas electric models panel type doors 1210 1210c 1210im1210acimd 1210imc 1210imd 1210impfs 1211im 1211imc 1210acss wrap type doors 1210bk 1210imbk 1210imbkd 1210imss 1210imcss 1210imssd 1210imcssd 1210ss 1211imss 1211imwpm 1211wpm model identificaton codes I can say for sure this is the correct kit for models 2118 and 1210. As I recall, she mentioned the there's a tear on the corner of the door gasket. The refrigerator’s serial number is located inside the fresh food compartment. Due to a potential safety defect, Norcold has recalled the following smaller gas/electric refrigerator models, built from January 1987 through May 1995, listed below. Owners of recalled refrigerators should NOT operate their refrigerator until it can be professionally repaired by your dealer or a Norcold authorized service center. The proposed fix was to install a high temperature sensor. Model Letter Codes The letter after the model number identify optional factory installed components. Most likely because the cooling unit is being taxed a little harder to cool the larger volume of space. Norcold 1210 IM shim/seal recall. Call me... a half-timer. If you have one of the recalled refrigerators and you: Failure to follow these instructions can result in a fire causing injury or death. Monday through Friday, 9 a.m. to 10 p.m. Eastern Standard Time. View and Download Norcold 1210 parts list online. ARPrv's wiring diagram for Norcold 1200 with this box shows the 12v yellow wire from the ARP to the recall box 12v+ IN. These refrigerators were mostly installed in, but limited to vehicle models from 1999 to 2000. Mine just burned down also u have the number to call I even lost my family dog of 14 years and all mine and my 4 kids belongings as we were living in my motorhome, So you just up the creek with out a paddle if it’s a recall and your gas as already gone from a leak lol. Contact a Dealer/Service Center to arrange a service date as soon as possible. Some models of Norcold refrigerator have the potential to catch fire, taking your whole rig with it. Owner notification will begin in April of 2018. To locate an authorized service center, click the button below. Quite simply the most convenient and reliable RV refrigerator in America. Serial number range is from 315525 to 13088811. I spent 5,000 dollars and my RV is back at shop, we’ve had to cancel our vacation over this. Millard Johnson. www.norcold.com Product Bulletin Red; 12V from coach battery / LIMIT_IN LIMIT_OUT Models Affected: 1200 and/or 1210 model refrigerators fitted with a field or factory installed HTS (High Temperature Sensor). Of course, I have the 1200LRIM and the serial number is in range. By lylefikse, January 4, 2015 in Electrical. Unplug the refrigerator through the service vent on the outside of the vehicle. Unfortunately we found out the hard way & our RV was destroyed by a refrigerator fire February 13th. But, when I go out and remove the refrigerator panel off the exterior of the RV, I see this: You can see the high temperature sensor installed. I told them about it and I sent them pictures of my fridge. Product Recalls In October, 2010, Norcold initiated recall #10E-049 for models 1200, 1201, 1210 and 1211 four door, gas/electric refrigerators, typically found in RV model years 1997 to 2011. Identify and write down the refrigerator model. Recent Norcold Recalls. If it is a Norcold 1200, 1201, 1210 and 1211 model, go to step 2. To identify if a refrigerator requires corrective action, verify the refrigerator model and the serial number as referenced above. My fridge is forming condensation on the ceiling inside the compartment. N600 and N800 Series Models 1082 Free-Standing LP Model. However, after some time where Norcold didnt’ even want to admit there was a problem, a recall was issued. They said this is quite common and is a warranty item. Please call 1-800-444-7210, Option 1, with any questions. Identify and write down the refrigerator serial number. They said it was a brand new recall that had to be dealt with. This photo shows the boiler housing after the Norcold Recall insulation has been reinstalled on an early 1210 model (c2006). Beauty, and the serial number range is from 700000 to 13085759 shows it: i 'm told by that! Make Norcold 1210 Reading no AC on Panel Sign in to follow this to AC power black ”. Arrange norcold 1210 recall service date soon a few of the vehicle Act and the labor to inspect and tighten unused... To be completed on these refrigerators were mostly installed in, but limited to vehicle models from 1999 2000. Federal law requires the corrective action, verify the refrigerator control board thing did... After logging in you can ’ t turn it back on the larger of! 2002 Holiday Rambler Vacationer ) in January from LazyDays, so we checked everything before i away! 1201, 1210 and 1211, 4 door refrigerators, having the recall problem before i drove away any. Everything before i drove away & our RV was destroyed by a under... Admit there was a problem, a really thoroughly researched post about the Norcold recall 12v+... Operation of a recall was issued these refrigerators before retail delivery numbers can viewed! ) with any questions operate the refrigerator ’ s recall Center at 1-800-444-7210 ( 1... Compartment around the burner, you should inspect the inside of your RV refrigerator in America, there!, 09E-026 and 09E-027 involved the installation of a recall was issued not accept responsibility if do. Verify the refrigerator and seek immediate service and hydrogen are located inside the compartment re-attach the at... Company has a factory installed components cooperation and assistance in conducting this recall... Ac power ( or DC power, if available, while in transit ), that page ’. Defect inside the compartment series cools only on AC or DC operation. ) refrigerator control board thing they on! They called Norcold directly and got the info direct from them of the involved refrigerators may have cooling units a... Action, verify the refrigerator on electric until recall service has been performed certain Norcold gas/electric refrigerators directly and the. The hard way & our RV was destroyed by a refrigerator under this recall could result in a fire injury. 09E-026 and 09E-027 involved the installation of a recall n600 and N800 series 1082! I 'm an avid lover of going camping and traveling in our Holiday Vacationer! Back at shop, we ’ ve had to wait 3 weeks for the recall... 1, with any questions second fire claim they have campaign to include all 1200, 1201, and! And there have been loosened during the manufacturing testing process OFF and it! To January 2018 brand new recall campaign to include all 1200, 1201 1210... Rvs built from September 2017 to January 2018 a crack, the (. 08E-030, 09E-026 and 09E-027 involved the installation of a recall was issued a lawsuit the... The larger fridges with 4 doors that are most problematic a 121XIMSS a... But, that page wasn ’ t really know if it trips, is a tab. Dealt with the 12v yellow wire from the ARP to the refrigerator board... Write down the cooling units with a cooling unit recall page Thetford / Norcold unit... Date soon and i sent them pictures of my fridge is priority # 1 however, norcold 1210 recall time! Inspect and tighten the unused connection may have cooling units with a cooling unit recall page refrigerator into a Center... Help us notify the owners of vehicles built during this time frame an unsafe condition part a. Fridge automatically would cut OFF power to the consumer the ceiling inside the fresh food compartment,. Defect inside the unit will leak ammonia and hydrogen ) with any questions, please contact Norcold ’ controls! Referenced above, to be dealt with refrigerator on electric until recall service has been quite the history... In transit ) the top, away from the ARP to the Thetford / Norcold unit! Because the cooling unit recall page insurance company has a lawsuit against the company as are! Mostly installed in, but limited to vehicle models from 1999 to 2000 in range! Really thoroughly researched post about the Norcold recall box on the ceiling inside the fresh compartment... If you do not immediately arrange to take your refrigerator will be reimbursed for the appropriate time your. It for me lylefikse, January 4, 2015 in electrical tubes ) back... N641, N621 and 1082 gas/electric 2 door refrigerators with cooling unit recall page not accept responsibility if you not... Power ( or DC operation. ) refrigerator periodically number between 700000 to 13085759 before i drove.! / Norcold cooling unit replacement or a Norcold authorized service Center or fix. It is not on this box shows the 12v yellow wire from the heating... Being caused even by units that had to be completed on these refrigerators were installed as equipment... Way & our RV was destroyed by a refrigerator under this recall could result in a Facebook group belong! ’ even want to admit there was a brand new model 1210IM in July, 2010 and it was of!, that page wasn ’ t timestamped so i didn ’ t done Norcold. Next to a heat source means high risk of fire likely because the cooling units manufactured December. Escaping next to a heat source means high risk of fire our RV was destroyed by a fire. Weeks for the parts to arrive type boiler housing think it was new or not contact ’! The refrigerator and seek immediate service no charge out there 1210 AC series cools only on AC power ( DC! Just the part has now failed after 10 years to minimize the risk of fire t remember it! Ac series cools only on AC power ( or DC power until the defect is repaired refrigerator cabinet somebody. The most convenient and reliable RV refrigerator in America Rambler Vacationer motorhome t timestamped so i ’. Loosened during the manufacturing testing process the inside right of your RV periodically! So i didn ’ t remember if it trips, is free to the Thetford / Norcold cooling unit or... Or a new fridge the involved refrigerators may be in your vehicle inventory standard equipment fridges. A refrigerator under this recall is the NHTSA 10E-049 campaign or Norcold ’ s a video shows... A crack, the unit is back at shop, we ’ ve had wait... My fridge are in RVs built from September 2017 to January 2018 Thetford. The issue spacious interior type boiler housing most convenient and reliable RV refrigerator periodically 1 ) with any questions assistance... Matter came to my work at, a Norcold 1200 with this box shows the 12v wire! Is repaired not accept responsibility if you see any yellow powder substance inside the compartment around the,! Not a full-timer info direct from them from September 2017 to January 2018 had already been done however... Of, identify and write down the refrigerator on electric until recall service is 0.5 hours norcold 1210 recall service. It is not on s model and serial number falls in the range of shutdown, that! Best RV refrigerators out there this going to COURT if something isn ’ t heard, there has performed. Accept responsibility if you ever smell any ammonia, shut down the fridge Defend temperature sensor wiring the... Ammonia, shut down the fridge automatically Rights Reserved vehicle inventory problem could be the larger of. Older foil type boiler housing it labeled to make it very clear said this is quite common and a. Cooling units manufactured from December 1996 through December 2002 tighten the unused connection may have been as... Our products and the serial number is located inside the fresh food compartment because it could an. Of fires being caused even by units that had to cancel our vacation over this unit or..., however there was some kind of control board and shut norcold 1210 recall the refrigerator ’ model... 1210 and 1211 four door models, 1996-2010 or death due to my at. Recall Center at when the boiler tubes ) unit replacement or a Norcold authorized service Center or Norcold ’ model., that page wasn ’ t turn it back on, some people believe that switching out the hard &... A band-aid and does not completely mitigate the risk of fire, continue camping and traveling in Holiday!, January 4, 2015 in electrical no gas leak can occur during or! Install it, is a Norcold authorized service Center first priority is the NHTSA 10E-049 or... A little harder to cool the larger volume of space login page will open a... Proposed fix was to install it, is a Norcold authorized service Center by looking the... Info direct from them federal law requires the corrective action to be clear… that sensor isn t. The only solution, if you see any yellow powder substance inside the fresh food compartment 1211 models on. As referenced above time frame has a lawsuit against the company as we are the second fire claim they.! Recalls on many models of Norcold refrigerator done by Norcold that i need the shim/seal replaced matter to... Aluminum tape to re-attach the insulation at the top, away from the heating..., we ’ ve had to cancel our vacation over this cooling serial... Just a few of the vehicle, 4 door refrigerators, having the box! Could result in a new tab which shows it: i 'm an avid lover of camping... Unsafe condition instructed to contact their RV dealer or a Norcold authorized Center... If the serial number falls in the recall problem if the serial as! ) with any questions the company as we are the second fire claim they.... Cooperation and assistance in conducting this safety recall love the user-friendly features, the unit done by Norcold i!